REQUEST FOR PROPOSAL  FOR  SUPPLY, INSTALLATION AND COMMISSIONING OF DATA CENTRE, SERVER AND NETWORK ENVIROMENT.

Download this RFP

EXECUTIVE SUMMARY 

NICO Technologies is looking to implement a secure, high speed server and network environment to be housed in a tier 3 data centre. The server environment cluster will be fully virtualized and redundant with real time replication to their Disaster recovery site in Lilongwe. The servers will be hosted in standard 42U server racks connected to SAN storage for increased capacity. A tape backup device will be connected for carrying out tape backups.

LOT 1: SERVER AND NETWORK ENVIROMENT 

1. SERVER INFRASTRUCTURE 

The preferred host servers are Oracle X series, for the specific requirement we are looking for model 7-2. There will be Seven (7) Oracle X7-2 servers at production site and Five (5) Oracle X7-2 Servers at the DR Site. Below are the system specifications for each server. 

Server Specification 

Quantity 

ORACLE SERVER X7-2: 1 RU BASE CHASSIS WITH MOTHERBOARD, EIGHT 2.5-INCH

DRIVE SLOTS DISK CAGE, 2 PSUS, SLIDE RAIL KIT, AND CABLE MANAGEMENT ARM

1

1 INTEL XEON GOLD 6140 18-CORE 2.3 GHZ PROCESSOR (FOR FACTORY INSTALLATION)

2

SHORT HEAT SINK (FOR FACTORY INSTALLATION)

2

ONE 32 GB DDR4-2666 REGISTERED DIMM (FOR FACTORY INSTALLATION)

8

SAS CABLES FOR 1U (FOR FACTORY INSTALLATION)

1

ONE 1.2 TB 10000 RPM 2.5-INCH SAS-3 HDD WITH MARLIN BRACKET (FOR FACTORY INSTALLATION)

2

PROCESSOR CLIP (FOR FACTORY INSTALLATION)

2

PCIE FILLER PANEL (FOR FACTORY INSTALLATION)

 

POWER CORD: SUN RACK 2 JUMPER, 2 METERS, C14RA PLUG, C13 CONNECTOR, 13 A (FOR FACTORY INSTALLATION)

2

ORACLE STORAGE DUAL PORT 16 GB OR 32 GB FIBRE CHANNEL PCIE HBA WITH 2

TRANSCEIVERS, QLOGIC (FOR FACTORY INSTALLATION)

2

ORACLE STORAGE 12 GB SAS PCIE RAID HBA, INTERNAL: 16 PORT AND 2 GB MEMORY (FOR FACTORY INSTALLATION)

1

ORACLE PREMIER SUPPORT FOR SYSTEMS - FIELD DELIVERY PARTNER

 
   

2. STORAGE INFRASTRUCTURE 

NICO Tech preference on storage platforms are IBM V5x and V7x ranges. For this specific requirement IBM V7000 storage is preferable. There shall be one (1) Storage device at production site and one( 1) at DR site with Seventy ( 70 )Terabytes usable capacity per site.  The hardware specification are as follows; 

Requirement 

Specification

Installed disks

 Mixed config with 4x1.6TB SSD and 20x2.4TB SAS

(10k rpm) capacity per disk shelf 

Maximum drives 

24 disks per shelf and up to 20 disk shelfs expansion 

Host Interface

SAN or direct-attached, 10 Gbps Ethernet (iSCSI),

16 Gbps Fibre Channel (FC, FC-NVMe) and 25 Gbps

Ethernet (iSCSI, iWARP, RoCE)

Fans and power supply

Fully redundant and hot swappable 

Management Software

IBM Spectrum Virtualize software 

Cores per controller System 

32 or 128

Advanced features included in each system 

Virtualization of internal storage, data migration, data reduction pools with thin provisioning, unmap and deduplication.

Advanced featured required   

Remote mirroring, Easy Tier, compression, external virtualization, encryption, FlashCopy, IBM Spectrum Control, IBM Spectrum Protect Snapshot

Warranty 

Hardware:

•                     3-year limited warranty

•                     Customer-replaceable units

•                     On-site service

•                     Next business day between 9 a.m. and 5 p.m. • Service upgrades available Software:

•                     Software maintenance agreement available

Replication Services

FlashCopy, IBM Spectrum Protect Snapshot, Metro

Mirror (synchronous), Global Mirror

(asynchronous)

Storage protocols supported

FC, FCoE, Iscsi

Host/client operating systems supported 

Windows 2000, Windows Server 2003, Windows

Server 2008, Windows Server 2012, Windows

Server 2016, Windows XP, Linux, Oracle Solaris,

IBM AIX, VMware ESX

 

     2.1        Core Storage Requirements

  • Must support up to 255 snapshots per volume with no noticeable degradation in performance.
  • Must be upgradable for higher performance and capacity with no data movement or migration required.
  • Must simultaneously support SAN (FC, FCoE and iSCSI) connectivity.
  • Must simultaneously support multiple disk technologies (SSD/FC/SATA/SAS).
  • At basic must support raid 5, 6 and 10 to guard against double disk drive failures, with no application performance degradation.
  • Must be able to support both thin provisioning and the ability to grow and shrink volumes without requiring storage or application downtime to rebuild RAID groups.
  • Must support backup/restore of data volumes/LUNs in less than 10 seconds, regardless of size.
  • Backups must not affect performance.
  • Must support block-level incremental replication of data over TCP/IP for backup and/or DR.
  • Must be able to clone data rapidly while minimizing physical storage space consumption without using additional space upon creation of the clone; only changes to the clone’s data should take up space.
  • Must support the backup of virtual machines without streaming data or the use of VMware Consolidated Backup (VCB).
  • Support server virtualization products such as VMware in a multiprotocol fashion (that is, over NFS, iSCSI, and FCP) by a single storage product.
  • The core storage must be upgradable from the initial capacity to at least 70TB usable without requiring data migration or a change of operating system.

     2.2       DR Replication Requirements 

  • The system must support block-level incremental data replication over TCP/IP in support of backups and/or disaster recovery.
  • The solution must support volume-level copying and mirroring within the same array, including the ability to easily and no disruptively attach mirrored copies to any connected host.
  • The solution must support scheduling of replication. The user must be able to create replication schedules that allow different sets to be replicated at different intervals.

3. STORAGE FABRIC REQUIREMENTS.

Preferred storage connectivity medium is fibre channel switches due to its high performance and stability. Our preferred vendor is Brocade and the preferred model is 6510. There will be two (2) Switches in the production environment and Two (2) at the DR site. The switches should come with licenses for 24 ports per switch.The hardware specifications for the brocade switches are as follows; 

  • Dual hot-swappable redundant power supplies
  • Up to 48 SFP/SFP+ ports
  • 1RU fixed form-factor switch
  • 4/8/16 Gbps auto-sensing, full-duplex (16 Gb FC SFP+ transceivers)

4. VIRTUALISATION TECHNOLOGY 

NICO Technologies is moving towards server virtualisation in view of achieving smaller data centres that not only will consume less power but provide scalability in infrastructure resource management and provisioning.  The choice of Hypervisor is VMware with standard licensing including vCentre for the central management of the systems. Oracle VM will only be used for servers that are running Oracle Databases. 

     4.1       Licensing 

The proposed virtualization solution must be licensed as per the requested number and configuration of servers keenly taking note of requested physical processors and memory. The license should be for the standard version of the virtualisation software.

     4.2        Warranty 

All virtualisation software must carry a minimum warranty of three (3) years.

5. TAPE BACKUP AND DATA REPLICATION

To ensure data backup and restoration the solution should backup to disk and then to tape. It should also be able to perform data backup at the DR site with a maximum of 5 minutes lag on replication.

     5.1        Backup and Replication Software

Veeam backup or VMware SRM with the licensing that meets the solution requirement.

     5.2       Tape Library device 

The preferred Tape library should be IBM TS3200. One tape library per site with a total of 50 tapes, LTO 7 and above.  

6. NETWORK INFRASTRUCTURE

NICO Tech preferred network infrastructure vender is CISCO. There will be Firewalls, Routers and Switches to be installed both at production site and DR site.

Below are the specifications for the network devices

ITEM

DESCRIPTION

QTY

 

INTERNET FIREWALL

 

ASA5516-FPWR-K9

ASA 5516-X with FirePOWER services, 8GE, AC, 3DES/AES

1

CON-SNT-ASA556F9

SNTC-8X5XNBD ASA 5516-X with FirePOWER services, 8GE

1

L-ASA5516-TAMC-1Y

Cisco ASA with FirePOWER Services IPS, Apps, AMP and URL Filtering

1

     

CPAP-SG3200-NGTP 

Check Point 3200 Next Generation Firewall

1

 

CISCO DISTRIBUTION SWITCH

 

WS-C3850-48T-E

Cisco Catalyst 3850 48 Port Data IP Services

2

CON-SNT-WSC388TE

SNTC-8X5XNBD Cisco Catalyst 3850 48 Port Data IP Serv

2

C3850-NM-4-1G

Cisco Catalyst 3850 4 x 1GE Network Module

2

 

 

 

WS-C3850-24T-E

Cisco Catalyst 3850 24 Port Data IP Services

2

CON-SNT-WSC388TE

SNTC-8X5XNBD Cisco Catalyst 3850 24 Port Data IP Serv

2

C3850-NM-4-1G

Cisco Catalyst 3850 4 x 1GE Network Module

2

 

CISCO ROUTER

 

ISR4321/K9

Cisco ISR 4321 (2GE,2NIM,4G FLASH,4G DRAM,IPB)

1

CON-SNT-ISR4321K

SNTC-8X5XNBD Cisco ISR 4321 (2GE,2NIM,4G FLASH,4G DRAM,IPB)

1

LOT 2: DATA CENTRE AND CIVIL WORKS

7. DATA CENTRE

Installation of datacentre equipment is to be done at NICO Technologies new data centre located in Blantyre. The installation should achieve and align to a Tier3 data centre requirements.  The following are the item to be installed in the server room

ITEM

SUBITEM

DESCRIPTION

POWER

UPS

30 KVA UPS (Uninterruptible power supply)

20 port PDUs (Type

C13)

Power Distribution Units with cables for Server Racks

Power Cabling

Power Cabling for Datacentre

Genset for Datacentre

60KVA Power generator for DC

Racks

Server RACKS

Server Racks for servers, storage and network devices

Floor

Raised Floor

Installation of Raised floor

Cable trays

Cable trays

Cable trays for power and data network

Cooling

Cooling system

installation of Colling system (HVAC)

Fire Suppression 

Fire Suppression 

installation of FM200 gas suppression system

Security

CCTV

Installation of CCTV

 

Door Access

Installation of Door access control system

8. POST IMPLEMENTATION SUPPORT AND MAINTENANCE 

Nico Technologies is looking to establish a relationship where the continued technical capacity of the implementing Partner is continually available. 

Engineering support from the partner must be availed post-implementation in the inevitable event that consultation and subsequent works around optimization of the deployed infrastructure may become necessary.  This support will also be leveraged for additions, deletions and general changes that may be necessary to achieve the fluid goals of the proposed infrastructure as NICO Technologies continues to grow.  This should be provided as a separate (mandatory) line item with a supporting proposal that meets the requirements as detailed above.

     8.1       Back to Back Vendor Support 

  • Access to vendor Technical Assistance Centres
  • Access to Vendor Knowledge Base
  • Hardware Replacement
  • Access to Minor upgrades and updates (software)

     8.2        Equipment and Engineering Support  

  • Onsite Engineering Support for Problem Resolution
  • Implementation Services for any additions or changes
  • Infrastructure Advisory Services for optimization of the solution provided

9. VENDOR ORGANISATION REQUIREMENTS 

  • Manufacturer Authorization for the Proposed solution
  • Copies of certifications for locally available implementing and supporting engineers. Minimum of 2 certified engineers in relation to the solution being provided.
  • Reference sites including contacts where they have implemented similar solution. Minimum of 2 sites in Malawi. 
  • Tax Clearance certificate
  • Company Profile
  • Certificate of Incorporation
  • Capabilities and resources to train NICO Technologies technical team on the solution

10.  SPECIAL INSTRUCTIONS 

  • Supplier to submit 2 documents a technical bid and a financial bid.
  • Technical bid should not include any financial information. A Technical bid containing material financial information shall be declared non-responsive.
  • Supplier to submit a bid with clear documentation of server architecture.

The supplier should clearly indicate whether they are bidding for LOT 1 or LOT 2.

  Download this RFP

 

Would you like us to quote or pitch for a prospective project?

We would genuinely love to hear from you, whatever your situation. Please get in touch directly using email or social media.

All Rights Reserved © 2018 NICO Technologies Limited.
Press enter to search
Press enter to search